Advantech EKI-9316P Series User Manual page 238

Industrial managed 16-port and 12-port full gigabit switch with poe/poe plus
Table of Contents

Advertisement

M
I
ANAGEMENT
NTERFACE
Interface Configuration
The Dynamic ARP Inspection Interface Configuration page allows users to enable or disable
trust rate for each interface, and assign rate limits and burst intervals. To access this page,
click Security > DHCP Snooping > Dynamic ARP Inspection > Interface Configuration.
Figure 3-176. Security > DHCP Snooping > Dynamic ARP Inspection > Interface Configuration
The following table describes the items in the previous menu.
Table 3-173. Security > DHCP Snooping > Dynamic ARP Inspection > Interface
Configuration
Parameter
Interface
Trust State
Rate Limit
No Limit
Burst Interval
Submit
Refresh
226
Click the drop-down menu to select the physical interface for which data is to be
displayed or configured.
Click the drop-down menu to enable or disable the trust state--indicates whether
the interface is trusted for Dynamic ARP Inspection purpose. If this object is set to
'Enable', the interface is trusted. ARP packets coming to this interface will be for-
warded without checking. If this object is set to 'Disable', the interface is not
trusted. ARP packets coming to this interface will be subjected to ARP inspection.
The factory default is Disable.
Enter a variable for the rate limit value for Dynamic ARP Inspection purpose. If the
incoming rate of ARP packets exceeds the value of this object for consecutively
burst interval seconds, ARP packets will be dropped. If this value is -1 there is no
limit. The Range is 0 to 300 pps. The factory default is 15pps (packets per second).
Enter a value to specify the value of Rate Limit will be configured to -1. If the rate
limit is -1 burst interval has no meaning, hence it is disabled.
Enter a value to specify the burst interval value for rate limiting purpose on this
interface. The Range is 1 to 15 seconds. If the rate limit is -1 burst interval has no
meaning. The factory default is 1 second.
Click Submit to update the switch with the values on the screen. If you want the
switch to retain the new values across a power cycle you must perform a save.
Click Refresh to update the data on the screen with the present state of the data in
the switch.
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eki-9312p series

Table of Contents