2.7.5

Wiring the Power Inputs

Caution! Do not disconnect modules or cabling unless the power is first switched
off.
The device only supports the voltage outlined in the type plate. Do not
use any other power components except those specifically designated
for the switch devic
Warning! Power down and disconnect the power cord before servicing or wiring
the switch.
There are two power inputs for normal and redundant power configurations. The
power input 2 is used for wiring a redundant power configuration. See the following
for terminal block connector views.

Figure 2.20 Terminal Receptor: Power Input Contacts

To wire the power inputs:
Make sure the power is not connected to the switch or the power converter before
proceeding.
1.
Loosen the screws securing terminal block to the terminal block receptor.
2.
Remove the terminal block from the switch.
3.
Insert a small flat-bladed screwdriver in the V1+/V1- wire-clamp screws, and
loosen the screws.
4.
Insert the negative/positive DC wires into the V+/V- terminals of PW1. If setting
up power redundancy, connect PW2 in the same manner.
V2+V2-
V1+V1-
1A@24V
PWR2
P-Fail
PWR1

Figure 2.21 Removing a Terminal Block

24
DC12-48V
EKI-7708 Series User Manual