Table 3-152. Security > Port Access Control > Supplicant Port Configuration (Continued)
Parameter
Start Period (secs)
Held Period (secs)
Authentication
Period (secs)
Maximum Requests
Submit
Refresh

Port Status

The Port Access Control Port Status page displays port access information for each
inter-face. To access this page, click Security > Port Access Control > Port Status.
Figure 3-156. Security > Port Access Control > Port Status
204
Enter the start period for the selected port. This command sets the value, in sec-
onds, of the timer used by the Supplicant state machine on this port to define peri-
ods of time after which it will send start message again on Authenticator absence.
The start period must be a number in the range of 1 and 65535. The default value
is 30 seconds. Changing the value will not change the configuration until the Sub-
mit button is pressed.
Enter the Held period for the selected port. The held period is the value, in sec-
onds, of the timer used by the supplicant state machine on the specified port to
determine when to send the next EAPOL start frame to the Authenticator on previ-
ous authentication failure. The Held period must be a number in the range of 1 and
65535. The default value is 60 seconds. Changing the value will not change the
configuration until the Submit button is pressed.
Enter the Authentication period for the selected port. The Authentication period is
the value, in seconds, of the timer used by the supplicant backend state machine
on the specified port to determine the timeout value for the EAPOL messages that
are sent out to the Authenticator. The Authentication period must be a number in
the range of 1 and 65535. The default value is 30 seconds. Changing the value will
not change the configuration until the Submit button is pressed.
Enter the Maximum start messages that can be sent on the selected port. The
maximum start request value is the maximum number of start messages to be sent
continuously to detect the presence/absence of the Authenticator. The maximum
start requests value must be in the range of 1 and 10. The default value is 3.
Click Submit to update the switch with the values on the screen. If you want the
switch to retain the new values across a power cycle you must perform a save.
Click Refresh to update the data on the screen with the present state of the data in
the switch.