Table 3-91. Switching > VLAN Setting > VLAN Membership (Continued)
Parameter
Tagging
VLAN ID - Individual/ Displays the VLAN Identifier for the new VLAN. (You can only enter data in this field
Range
VLAN Name
VLAN ID
VLAN Participation
All
VLAN Participation
Convert VLAN Type
to Static
VLAN Type
Error Console
Interface
Status
Submit
Clear Log
144
Displays the tagging behavior for this port in this VLAN. The factory default is
Untagged. The possible values are:

Tagged - all frames transmitted for this VLAN will be tagged.
Untagged - all frames transmitted for this VLAN will be untagged.

when you are creating a new VLAN.)Specify the VLAN Identifiers for the VLANs
being created or deleted. Single or Multiple VLANs can be specified at once. This
field can accept single VLAN ID or range of VLAN IDs or a combination of both in
sequence separated by ','. You can specify individual VLAN ID. Eg: 10 You can
specify the VLAN range values separated by a '-'. E.g. 10-13 You can specify the
combination of both separated by ','. Eg: 12,15,40-43,1000-1005,2000 The range
of the VLAN ID is 2 to 4093.
Displays the use this optional field to specify a name for the VLAN. It can be up to
32 alphanumeric characters long, including blanks. The default is blank. VLAN ID 1
always has a name of 'Default'.
Displays the VLAN ID. The range of the VLAN ID is 1 to 4093.
Displays the VLAN participation selection of all the interfaces. By default, the field
is disabled. Set the checkbox to enable the field.
Displays the VLAN participation selection. By default, the field is disabled. Set the
checkbox to enable the field.
Displays the VLAN type conversion option. A VLAN that is created by GVRP regis-
tration initially has a type of 'Dynamic'. By default, the field is disabled. Set the
checkbox to enable the field.
Displays the VLAN type. You cannot change the type of the default VLAN (VLAN ID
= 1): it is always type 'Default'. When you create a VLAN, using this screen, its type
will always be 'Static'. A VLAN that is created by GVRP registration initially has a
type of 'Dynamic'.
Displays the reason for failure if any occurred during creation or deletion of VLANs.
Displays the port associated with the fields on this line.
Displays the current value of the participation parameter for the port.
Click Submit to update the switch with the values on the screen. If you want the
switch to retain the new values across a power cycle you must perform a save.
Click Clear Log to reset the log history.