Chapter 13
10) Remove the cleaning blade from the cleaning blade assembly.
11) Butt the turned or replaced cleaning blade [7] against the rear of the blade retaining plate [8] while keeping the edge flush.
When butting the blade, be sure to use your fingers to keep it firmly in contact.
12) Tighten the screws on the blade retaining plate in the sequence indicated.
- From 1 to 5, tighten temporarily.
While keeping the blade down with the plate, tighten the screws temporarily.
13-44
[5]
F-13-45
Flush.
[7]
[8]
F-13-46
10
5
8
7
3
1
9
2
F-13-47
[6]
[4]
6
4