Chapter 17
Sub-item
Making Cassette-/Manual Feed-Related Adjustments
If you have cleared the RAM on the DC controller PCB, enter the settings indicated on the service label.
C4-STMTR
C4-A4R
MF-A4R
MF-A6R
MF-A4
C3-LVOL
C3-HVOL
C4-LVOL
C4-HVOL
<EXP-LED>
Sub-item
PRE-TR

17.4.1.4 Copier List

<LAMP>
Sub-item
L-DATA
<AE>
17-80
COPIER > ADJUST > CST-ADJ
Use it to enter a paper width basic value for the cassette 4. (STMTR)
<Setting range> 0 to 255
If you have replaced the paper width detecting VR, execute the following in service
mode: FUNCTION> CST.
Use it to enter a paper width basic value for the cassette 4. (A4R)
<Setting range> 0 to 255
If you have replaced the paper width detection VR, execute the following in service
mode: FUNCTION> CST.
Use it to enter a paper basic value for the manual feed tray. (A4R)
<Setting range> 0 to 255
If you have replaced the paper width detecting VR, execute the following in service
mode: FUNCTION> CST.
Use it to enter a paper width basic value for the manual feed tray. (A6R)
<Setting range> 0 to 255
If you have replaced the paper width detecting VR, be sure to execute the following
service mode: FUNCTION> CST.
Use it to enter a paper width basic value for the manual feed tray. (A4)
<Setting range> 0 to 255
If you have replaced the paper width detecting VR, execute the following in service
mode: FUNCTION> CST.
Use it to enter a stack height for the cassette 3. (50 sheets)
<Setting range> 0 to 255
Use it to enter a stack height for the cassette 3. (250 sheets)
<Setting range> 0 to 255
Use it to enter a stack height for the cassette 4. (50 sheets)
<Setting range> 0 to 255
Use it to enter a stack height for the cassette 4. (250 sheets)
<Setting range> 0 to 255
COPIER > ADJUST > EXP-LED
Use it to enter the output adjustment value for the pre-transfer exposure lamp.
<Setting range> 20 to 80
COPIER > ADJUST > LAMP
Use it to enter the scanning lamp intensity data.
<Setting range> 0 to 1023
- A higher input value increases the intensity.
- A lower input value decreases the intensity.
If the output shows faulty images after execution of the following, enter the values
indicated on the service sheet: COPIER> FUNCTION> CCD> CCD-ADJ.