Canon ImageRunner iR8500 Series Service Manual page 945

Hide thumbs Also See for ImageRunner iR8500 Series:
Table of Contents

Advertisement

Sub-item
DC-CON
Clearing RAM on the DC controller circuit board
The RAM is cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select COPIER>FUNCTION>MISC-P>P-PRINT to print out the contents of
the service mode.
2) Select this item and press the OK key.
3) Turn the main power switch OFF and ON.
4) Enter the P-PRINT output data as required.
R-CON
Clearing RAM on the reader controller circuit board
The RAM is cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select COPIER>FUNCTION>MISC-P>P-PRINT to print out the contents of
the service mode.
2) Select this item and press the OK key.
3) Turn the main power switch OFF and ON.
4) Enter the P-PRINT output data as required.
JAM-HIST
Clearing the jam history
The jam history is cleared when the OK key is pressed.
<Operating procedure>
1) Select this item and press the OK key.
ERR-HIST
Clearing the error history
The error history is cleared when the OK key is pressed.
<Operating procedure>
1) Select this item and press the OK key.
PWD-CLR
Clearing the password of the system administrator set in user mode
The password is cleared when the OK key is pressed.
<Operating procedure>
1) Select this item and press the OK key.
ADRS-BK
Clearing the address book on the reader controller circuit board
The address book is cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
CNT-MCON
Clearing the service counter incremented by the main controller circuit board
The password is cleared when the OK key is pressed.
<Operating procedure>
1) Select this item and press the OK key.
CNT-DCON
Clearing a service counter incremented by the DC controller circuit board
The password is cleared when the OK key is pressed.
This applies to SORT, FIN-STPR, SADDLE, and SDL-STPL under
COPIER>COUNTER>DRBL-2.
<Operating procedure>
1) Select this item and press the OK key.
MMI
Clearing the following settings in User mode
- Backup data (user-defined values) for copy operations
- Backup data (user-defined values) of common settings
- Various backup data (user-defined values), excluding fax
The settings are cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
MN-CON
Clearing RAM on the main controller circuit board
The RAM is cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select COPIER>FUNCTION>MISC-P>P-PRINT to print the contents of the
service mode.
2) Select this item and press the OK key.
3) Turn the main power switch OFF and ON.
4) Enter the P-PRINT output data as required.
CARD
Clearing the card ID (department) related data
The card ID related data is cleared when the main power switch is turned OFF and
ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
ALARM
Clearing the alarm log
The alarm log is cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
SLT-CLR
Clearing the salutation setting
<Operating procedure>
1) Select this item and press the OK key.
COPIER > FUNCTION > CLEAR
Description
Chapter 17
Level
1
1
1
1
1
1
1
1
1
1
1
1
1
17-101