Canon ImageRunner iR8500 Series Service Manual page 1032

Hide thumbs Also See for ImageRunner iR8500 Series:
Table of Contents

Advertisement

Chapter 17
Sub-item
IFAX-LIM
DF-BLINE
THICK-PR
TEMP-TBL
DRM-H-SW
DEV-IDLR
BK-BD-1
BK-BD-2
BK-BD-3
BK-BD-4
BK-BD-5
BK-BD-6
BK-BD-7
BK-BD-8
BK-BD-9
BK-BD-10
17-188
COPIER > OPTION > BODY
Description
Limiting the number of output lines when a large amount of data has been
received by IFAX.
<Setting value>
0: No limit
0 to 999 [Default: 500]
Taking corrective measures against a black line caused by dust on the platen
at flow read
<Setting value>
0: No corrective measures [Default]
1: Corrective measures
Use it to set the potential control mechanism for thick paper mode.
<Setting value>
0: use value determined by potential control in plain paper mode (default)
1: use value determined by potential control in transparency mode
Use it to select a fixing temperature.
<Setting value>
0: 198 deg C (default)
1: 203 deg C
2: 193 deg C
3: 188 deg C
4: 183 deg C
Use it to set the night drum heater OFF mode.
<Setting value>
0: night drum heater ON (default)
1: monitor ambient humidity every 2 hr; turn off drum heater if absolute water
content is 9 g or less
Use it to set black band developing forced idle rotation mode used at time of
power-on.
<Setting value>
0: execute black band developing idle rotation sequence at power-on if 2000
copies or more were made on previous day and, in addition, absolute water
content is 16 g or more (default)
1: execute black band developing idle rotation sequence at power-on at all
times
Use it to set black band monthly remedial mode (for January).
<Setting value>
0: do not execute if absolute water content is less than 9 g
execute every 200 copies if absolute water content is 9 g or more (default)
1: execute black band sequence every 60 copies
2: execute black band sequence every 20 copies
3: execute black band sequence every 6 copies
Use it to set black band monthly remedial mode (for February).
<Setting value>
Same as for January.
Use it to set black band monthly remedial mode (for March).
<Setting value>
Same as for January.
Use it to set black band monthly remedial mode (for April).
<Setting value>
Same as for January.
Use it to set black band monthly remedial mode (for May).
<Setting value>
Same as for January.
Use it to set black band monthly remedial mode (for June).
<Setting value>
Same as for January.
Use it to set black band monthly remedial mode (for July).
<Setting value>
Same as for January.
Use it to set black band monthly remedial mode (for August).
<Setting value>
Same as for January.
Use it to set black band monthly remedial mode (for September).
<Setting value>
Same as for January.
Use it to set black band monthly remedial mode (for October).
<Setting value>
Same as for January.
Level
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Advertisement