Canon ImageRunner iR8500 Series Service Manual page 975

Hide thumbs Also See for ImageRunner iR8500 Series:
Table of Contents

Advertisement

Sub-item
COTDPC-D
Use it to set toner save mode.
<Setting value>
0: do not use toner save mode (default)
1: VDT-20V of coy image, VDT-P25V of print image (target of -10 %,
approx.)
2: VDT-40V of copy image, VDT-P-50V of print image (target of -20 %,
approx.)
3: VDT-60V of copy image, VDT-P-75V of print image (target of -30 %,
approx.)
RMT-LANG
Changing the remote UI language from web
<Adjustment method>
Select a language code with the + or - key.
IFAX-LIM
Limiting the number of output lines when a large amount of data has been
received by IFAX.
<Setting value>
0: No limit
0 to 999 [Default: 500]
DF-BLINE
Taking corrective measures against a black line caused by dust on the platen
at flow read
<Setting value>
0: No corrective measures [Default]
1: Corrective measures
THICK-PR
Use it to set the potential control mechanism for thick paper mode.
<Setting value>
0: use value determined by potential control in plain paper mode (default)
1: use value determined by potential control in transparency mode
TEMP-TBL
Use it to select a fixing temperature.
<Setting value>
200 V
0: 183 deg C
1: 193 deg C
2: 178 deg C
3: 173 deg C
4: 168 deg C
208 V/230 V
0: 193 deg C
1: 198 deg C
2: 188 deg C
3: 183 deg C
4: 178 deg C
DRM-H-SW
Use it to set the night drum heater OFF mode.
<Setting value>
0: night drum heater ON (default)
1: monitor ambient humidity every 2 hr; turn off drum heater if absolute water
content is 9 g or less
DEV-IDLR
Use it to set black band developing forced idle rotation mode used at time of
power-on.
<Setting value>
0: execute black band developing idle rotation sequence at power-on if 2000
copies or more were made on previous day and, in addition, absolute water
content is 16 g or more (default)
1: execute black band developing idle rotation sequence at power-on at all
times
BK-BD-1
Use it to set black band monthly remedial mode (for January).
<Setting value>
0: do not execute if absolute water content is less than 9 g
execute every 200 copies if absolute water content is 9 g or more (default)
1: execute black band sequence every 60 copies
2: execute black band sequence every 20 copies
3: execute black band sequence every 6 copies
BK-BD-2
Use it to set black band monthly remedial mode (for February).
<Setting value>
Same as for January.
BK-BD-3
Use it to set black band monthly remedial mode (for March).
<Setting value>
Same as for January.
BK-BD-4
Use it to set black band monthly remedial mode (for April).
<Setting value>
Same as for January.
BK-BD-5
Use it to set black band monthly remedial mode (for May).
<Setting value>
Same as for January.
COPIER > OPTION > BODY
Description
Chapter 17
Level
2
2
2
2
2
2
2
2
2
2
2
2
2