Code
Cause
0003 The horizontal registration detection
movement for the preceding sheet does not end
within 5 sec at the start of a horizontal
registration search during printing.
E065
There is an error in the high-voltage output to the transfer charging assembly.
0000 An error (leakage) is detected in the high-
voltage output to the primary charging
assembly.
E067
There is an error in the high-voltage output.
0000 An error is detected in two or more of the
following at the same time: the primary high
voltage, pre-transfer high voltage, transfer
high voltage, and separation high voltage. Or,
an error (leakage) in the high-voltage output to
the separation charging assembly is detected.
E068
There is an error in the high-voltage output to the separation charging assembly.
0000 An error (leakage) to the high-voltage output
to the separation charging assembly is
detected.
E069
There is an error in the high-voltage output to the transfer charging assembly.
0000 An error (leakage) is detected in the high-
voltage output to the transfer charging
assembly.
E100
The BD PCB is faulty.
0000 The BD signal does not arrive within 1 sec
after the laser drive signal has been generated.
Or, the BD signal does not arrive for 1 sec or
more while the laser remains ON.
E110
The rotation of the laser scanner motor is faulty.
0000 The constant speed rotation signal (LM-RDY)
does not arrive for 20 sec or more after the
laser scanner motor (M4) drive signal has been
generated.
E111
The rotation of the laser motor cooling fan is faulty.
0000 The lock signal arrives for 5 sec or more
although the laser motor cooling fan (FM1) is
being driven.
E121
The rotation of the laser cooling fan (1/2) is faulty.
0001 The lock signal arrives for 5 sec or more
although the laser cooling fan 1 (FM3) is being
driven.
0002 The lock signal arrives for 5 sec or more
although the laser cooling fan 2 (FM5) is being
driven.
E202
There is an error in the detection of the scanner home position.
Remedy
- Replace the horizontal registration sensor.
- Replace the horizontal registration motor.
- Check if the manual feed tray open/closed detecting
switch is mounted properly.
- Replace the stackless feed driver PCB.
- Replace the DC controller PCB.
- Check if the primary charging assembly is mounted
properly and also check if there is no contamination.
- Check if the connector (T601, J723, J730) of the HV-
DC PCB is mounted properly and also check the wiring.
- Replace the HV-DC PCB.
- Check if the primary charging assembly, pre-transfer
charging assembly, transfer charging assembly and
separation charging assembly are mounted properly.
- Check if the connector (J722, J723, J730) of the HV-
DC PCB is mounted properly and also check the wiring.
- Replace the HV-DC PCB.
- Replace the HV-AC PCB.
- Check if the transfer charging assembly and separation
charging assembly are mounted properly.
- Check if the connector (J722, J723, J730, J734) of the
HV-DC PCB and the connector (J741, J742) of the HV-
AC PCB are mounted properly.
- Replace the HV-AC PCB.
- Replace the separation charging assembly.
- Replace the pre-transfer charging assembly.
- Check if the transfer charging assembly and separation
charging assembly are mounted properly.
- Check if the connector (T701, J723, J730) of the HV-
DC PCB is mounted properly and also check the wiring.
- Replace the HV-DC PCB.
- Replace the pre-transfer charging assembly.
- Check if the BD PCB, laser driver PCB and DC
controller are connected properly.
- Replace the BD PCB.
- Replace the laser scanner unit.
- Replace the DC controller PCB.
- Check if the connector (J762) of the laser scanner
motor driver PCB is mounted properly.
- Check if the connector (J503) of the DC controller
PCB is mounted properly.
- Replace the laser scanner unit.
- Replace the DC controller PCB.
- Check if there is no foreign material in the rotation
assembly of the laser motor cooling fan.
- Check if the connector (J503) of the relay PCB is
mounted properly.
- Replace the laser motor cooling fan.
- Replace the DC controller PCB.
- Check if there is no foreign material in the rotation
assembly of the laser cooling fan 1.
- Check if the connector (J503) of the relay PCB is
mounted properly.
- Replace the laser cooling fan 1.
- Replace the DC controller PCB.
- Check if there is no foreign material in the rotation
assembly of the laser cooling fan 2.
- Check if the connector (J503) of the relay PCB is
mounted properly.
- Replace the laser cooling fan 2.
- Replace the DC controller PCB.