Canon ImageRunner iR8500 Series Service Manual page 954

Hide thumbs Also See for ImageRunner iR8500 Series:
Table of Contents

Advertisement

Chapter 17
Sub-item
CNT-MCON
CNT-DCON
MMI
MN-CON
CARD
ALARM
SND-STUP
CA-KEY
<MISC-R>
SCANLAMP
<MISC-P>
17-110
COPIER > FUNCTION > CLEAR
Clearing the service counter incremented by the main controller circuit board
The password is cleared when the OK key is pressed.
<Operating procedure>
1) Select this item and press the OK key.
Clearing a service counter incremented by the DC controller circuit board
The password is cleared when the OK key is pressed.
This applies to SORT, FIN-STPR, SADDLE, and SDL-STPL under
COPIER>COUNTER>DRBL-2.
<Operating procedure>
1) Select this item and press the OK key.
Clearing the following settings in User mode
- Backup data (user-defined values) for copy operations
- Backup data (user-defined values) of common settings
- Various backup data (user-defined values), excluding fax
The settings are cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
Clearing RAM on the main controller circuit board
The RAM is cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select COPIER>FUNCTION>MISC-P>P-PRINT to print the contents of the
service mode.
2) Select this item and press the OK key.
3) Turn the main power switch OFF and ON.
4) Enter the P-PRINT output data as required.
Clearing the card ID (department) related data
The card ID related data is cleared when the main power switch is turned OFF and
ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
Clearing the alarm log
The alarm log is cleared when the main power switch is turned OFF and ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
Clearing the send-read settings
The send-read settings are cleared when the main power switch is turned OFF and
ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
Clearing the CA certificate and key pair
The CA certificate and key pair are cleared when the main power switch is turned
OFF and ON.
<Operating procedure>
1) Select this item and press the OK key.
2) Turn the main power switch OFF and ON.
COPIER > FUNCTION > MISC-R
Sub-item
Lighting the LED lamp (for document lighting)
<Operating procedure>
1) Select this item.
2) Press the OK key. The LED lamp (for document lighting) is lit for three
seconds.
Description
T-17-135
Description
Level
1
1
1
1
1
1
2
2
Level
1

Advertisement

Table of Contents
loading

Table of Contents