2.1 Making Pre-Checks

2.1.1 Selecting the site

iR105i/iR105+ / iR9070
The site of installation must meet the following requirements; if possible, visit the user's before delivery of the machine:
1) The site must provide with a power outlet that is rated to suit the machine and that can be used exclusively by the machine; 200V Model (180 to 220V,
15A or more), 208V Model (188 to 228V, 12A or more), 230V Model (198 to 264V, 13A or more).
2) Temperature and humidity must be within the extent of the following figure. Particularly, be sure to avoid areas near water faucets, water boilers,
humidifiers, and refrigerators.
<Guaranteed Environment Zone>
[A] Zone A: All items of the Quality Standard are satisfied.
[B] Zone B: In the Quality Standard, there are items that are inferior to Zone A or not
satisfied.
[C] Zone C: There are no safety problems, no malfunctions, and no improper
indications. Copying is performed properly.
3) The site must not be near a source of fire, subject to dust or ammonium gas, or exposed to direct rays of the sun. As necessary provide curtains.
4) The level of ozone generated by the machine will not affect the health of individuals around it. Some, however, may find its odor unpleasant as while
remaining in contact with it for long hours. Be sure that the room is well ventilated.
5) Make sure that the feet of the machine will remain in contact with the floor, and the machine will be kept level.
6) Make sure that the machine will be at least 10 cm away from any walls, allowing enough space for work.
7) Make sure that the area is well ventilated. If multiple machines are installed, in particular, be sure that the exhaust of another will not be drawn by the
machine. Be sure also not to install a machine near an air vent.
(%RH)
100
[C]
90
85
[B]
75
70
50
25
20
15
10
5
0
10
15
7.5
Exhaust
[A]
20
25
30
23
27.5
32.5
F-2-1
Wrong 1
F-2-2
35
40
(degC)
Chapter 2
0008-8679