Brocade Communications Systems WFT-2D User Manual page 572

San user manual
Table of Contents

Advertisement

12
Ports
TABLE 52
Field
Selected Connection Properties table
520
Port connection properties (Continued)
dB Loss (dB)
Area ID (hex)/Port Index (hex)
Blocked
Buffers Allocated
Buffers Desired
Circuits
Compression
Connected Switch
Cost
Distance Actual (km)
Distance Estimated (km)
ED TOV
Encryption
Fabric
FC Address
FC Port #
FCIP Capable
Flag (FICON related)
Forward Error Correction (FEC)
GE Port #
InBand Management State
iSCSI Capable
L2 Mode
LAG ID
Locked Port Type
Long Distance Setting
MAC Address
Manufacturer
Description
The power loss (dB) value between the source and destination ports.
Only available when historical performance data collection is
enabled.
For Fabric OS devices, this field requires firmware version 6.2.2d,
6.3.2c, 6.4.1a, or 6.4.2 or later.
Does not display in Professional edition or if SNMP commnunication
fails during discovery or if either switch is not reachable through ISL
or IFL.
The connected device port information.
The area identifier, in hexadecimal, of the switch-to-product
connection.
The configuration of the switch (blocked or unblocked).
The number of buffers allocated.
The number of buffers required but not allocated.
The circuit number of the connected switch.
Whether compression is enabled or disabled.
The name of the connected switch.
The cost of the ISL link.
The actual distance (in km) for -end port connectivity.
The estimated distance (in km) for -end port connectivity.
The Error Detect timeout value, in milliseconds, of the connected
switch. This variable is used to flag a potential error condition when
an unexpected response is not received.
Whether encryption is enabled or disabled.
The fabric name.
The Fibre Channel (FC) address of the switch.
The FC port number of the switch.
Whether the switch is FCIP capable or not.
Whether a FICON-related flag is on or off.
Whether FEC is enabled or disabled.
The GE port number of the switch.
Whether inband management is enabled or disabled.
Whether the switch is iSCSI capable or not.
Whether the switch is in L2 mode or not.
The LAG identifier.
The port type of the locked product.
Whether the connection is considered to be normal or longer
distance.
The MAC address of the switch.
The name of the manufacturer.
Brocade Network Advisor SAN User Manual
53-1003154-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Network advisor 12.3.0

Table of Contents