CHAPTER 19 8/10-BIT A/D CONVERTER
[Bit 9] STRT: start
•
Set this bit by writing "1" to start A/D conversion.
•
For restarting, write this bit again.
•
When stop mode is set, operation cannot be restarted by an operational function.
•
This bit is initialized to "0" at reset.
•
The bite/words instructions read "1".
•
The read-modify-write type instructions read "0".
Note:
Do not execute forced stop and software start simultaneously. (BUSY = 0, STRT = 1)
[Bit 8] Reserved
In write operations, write "0".
364