Configuring Snmp V3 Access - Motorola WiNG 4.4 Reference Manual

Table of Contents

Advertisement

3. Modify the
Community Name
the original entry is required to match the name used within the remote network management software.
4. Modify the existing read-only (R)
remote device to retrieve information, while read/write access allows a remote device to modify settings.
5. Click
OK
to save and add the changes to the running configuration and close the dialog.
6. Refer to the
Status
something goes wrong in the transaction between the applet and the switch
7. Click
Cancel
to return back to the SNMP v1/v2 screen without implementing changes.

7.3.2 Configuring SNMP v3 Access

SNMP Version 3 (SNMPv3) adds security and remote configuration capabilities to previous versions. The SNMPv3
architecture introduces the User-based Security Model (USM) for message security and the View-based Access Control
Model (VACM) for access control. The architecture supports the concurrent use of different security, access control, and
message processing techniques.
Refer to the
v3
screen to review the current SNMP v3 configuration. An Existing User Name can be selected and edited,
enabled or disabled. .
NOTE: The SNMP undo feature is not supported in this product.
To review existing SNMP v3 definitions:
1. Select
Management Access
2. Select the
V3
tab from within the SNMP Access screen.
used to associate a site-appropriate name for the community. The name revised from
access
or read/write (RW)
field for the current state of the requests made from applet. This field displays error messages if
>
SNMP Access
access
for the community. Read-only access allows a
from the main menu tree.