5 - 44 WiNG 4.4 Switch System Reference Guide
4. Refer to the following redundancy member information:
IP Address
Status
Adoption Count
Adoption Capacity
Mode
License Count
Image Version
First Seen
Last Seen
HB Sent
HB Received
Updates Sent
Updates Received
Radio Portals
Displays the IP addresses of the members of the redundancy group. There
are a minimum of 2 members needed to define a redundancy group,
including this current module.
Displays the current status of this group member. This status could have the
following values:
Configured - The member is configured on the current wireless service
module.
Seen - Heartbeats can be exchanged between the current switch and this
member.
Invalid - Critical redundancy configuration parameter(s) of the peer
(heartbeat time, discovery time, hold time, Redundancy ID, Redundancy
Protocol version of this member) do not match this switch's parameters.
Not Seen - The member is no more seen by this switch.
Established - The member is fully established with this current module and
licensing information already been exchanged between this switch and the
member.
Displays the number of Access Ports adopted by this member.
Displays the maximum number of Access Ports this member is licensed to
adopt. For information on licensing rules impacting redundancy group
members, see
Redundancy Group License Aggregation Rules on page
The Redundancy Mode could be Active or Standby depending on the mode
configuration on the member. Refer to the Configuration screen to change
the mode
Displays the number of port licenses available for this switch. For
information on licensing rules impacting redundancy group members, see
Redundancy Group License Aggregation Rules on page
Displays the image version currently running on this member. Is the
selected version complimentary with this switch's version?
Displays the time this member was first seen by the switch.
Displays the time this member was last seen by the switch.
Displays the number of heartbeats sent from the switch to this member
since the last reboot of the switch.
Displays the number of heartbeats received by the switch since the last
reboot.
Displays the number of updates sent from the switch since the last reboot.
Updates include, authorization level, group authorization level and number
of Access Ports adopted.
Displays the number of updates received by the current switch from this
member since the last reboot.
Displays the number of radio portals detected on each redundancy member
listed.