Configuring Redundant Site Controller; Performing Site Controller Hardware Pre-Checks - Motorola DIMETRA MTS 4 Installation, Configuration, And Service Manual

Dimetra ip scalable (dips); dimetra ip compact (dipc)/scalable dimetra ip (sdip); dimetra ip micro/dimetra ip lite
Table of Contents

Advertisement

Applicant: Motorola Solutions
392 | Expansion Options
3066544B17
11 Remove the Terminator from the CAN2 output on the Power Supply Unit and connect the CAN Bus cable
according to the scheme below:
Part no
3066544B03
12 Connect the power cables to the MTS Power Supply Units.

Configuring Redundant Site Controller

Note: Redundant Site Controller feature is supported by MTS Software releases:
Note: On power up of the Standby Site Controller the Base Radios may dekey and reset. Base Radios will
automatically recover and key up again within 20 seconds.
Process:
1 Perform Site Controller Hardware Pre-Checks.
See
Performing Site Controller Hardware Pre-Checks on page
2 Configure the Site Controller Configuration Files.
See
Configuring Site Controller Configuration Files on page
3 Configure Ethernet ports connecting the two Site Controllers.
See
Configuring Ethernet Ports on page
4 Configure the ID values of the Site Controllers.
See
Configuring Site Controller IDs on page

Performing Site Controller Hardware Pre-Checks

Procedure:
1 Ensure that both Site Controllers are correctly installed and are running identical software applications, Boot
images and configuration files.
2 In order for the Redundant Site Controller feature to work correctly, the Site Controller and BR Boot1 version
must be:
TSC_RLJ_BOOT1–R06.40.07 or later for SC.
BRC_RLJ_BOOT1–R06.40.05 or later for Base Radio.
3 Check that the redundant Site Controller Ethernet Link cables are connected correctly, as shown in
Connections.
4 Proceed to
Send Feedback
| September 2014 | 6802800U74-AD
Redundant CTRL signal
cable
Note: Make sure to follow the color indications on both the cables as well as on the Site
CONTROLLER.
Cable type
CAN Bus cable
MTS SPU R5.2_002.34 or later
MTS SPU R6.0_001.12 or later
Note: The Boot1 version can be checked on the Site Controller and BRs by resetting the Site
Controller/BR and interrupting the startup sequence when prompted to go into Boot1 mode. The
software version is displayed when entering Boot1 mode.
Configuring Site Controller Configuration Files on page 393
SC1 / RedOut
From
SC2 / CAN
392.
393.
393.
394.
Equipment Type: ABZ89FC5827 / 109AB-5827
SC2 / RedIn
To
PSU2 / CAN2
Cable
below.