Motorola WiNG 4.4 Reference Manual page 561

Table of Contents

Advertisement

Possible Problem
DHCP is not enabled on a
Gigabit Ethernet
interface
All else...
C.1.1.3 Unable to Connect to the Switch using Telnet or SSH
The Motorola Solutions RF Series Switch is physically connected to the network, but connecting to the switch using SSH
or Telnet does not work.
The table below provides suggestions to troubleshoot this issue.
Possible Problem
Telnet is not enabled
and/or SSH is disabled
Max sessions have been
reached
Primary LAN is not
receiving Telnet or SSH
traffic
All else...
C.1.1.4 Web UI is Sluggish, Does Not Refresh Properly, or Does Not Respond
When configuring the switch, it is easy to overlook the fact that the host computer is running the browser while the
Motorola Solutions RF Series Switch is providing the data to the browser. Occasionally, while using the Web UI the switch
does not respond or appears to be running very slow; this could be a symptom of the host computer or the network, and
not the switch itself. The table below provides suggestions to troubleshoot this issue.
Possible Problem
Bad connection between
switch and console
system
Slow transmission of
data packets
Access ports may try to
adopt while country code
is not set
Packet storm
Overburdened with a
large number of Access
Ports
Suggestions to Correct
• Enable DHCP for the port by using the CLI command or the Web UI to
enable DHCP on the port connected to your external network.
• Verify that DHCP packets are being sent to the port using a sniffer tool
• If DHCP packets are seen, check to ensure that the switch is not
configured for a static IP on the port.
Contact Motorola Solutions Support.
Suggestions to Correct
Verify that Telnet or SSH are enabled by using the CLI or Web UI (By default,
telnet is disabled.).
Maximum allowed sessions is 8 concurrent users connected to a switch. Verify
that the threshold has not been reached.
Verify that Telnet and SSH traffic is allowed on the primary VLAN.
Contact Motorola Solutions Support.
Suggestions to Correct
Verify the line between the switch and the host computer is functioning
normally.
Verify the data packets are being sent to and from the switch using a
sniffer tool.
Set the country name for the switch, which is set to "none" by default.
Check Syslog for any type of a packet storm.
With large numbers of Access Ports, changing the configuration quickly
may cause the switch to not refresh properly, at least immediately
following configuration.
C - 3

Advertisement

Table of Contents
loading