COPIER>ADJUST>HV-PRI
OFSTACK2
AdjofBkclrchargeACcurrent:1/2SPD
Lv.1
Details
ToadjusttheoffsetofthechargeACcurrentforBkat1/2speed.
Asthevalueisincrementedby1,theoffsetisincreasedby50
uA.
Increasethevaluewhenthedensityislowanddecreasethe
valuewhenthedensityishighoraspottedimageoccurs.
•
Usecase
Attheoccurrenceofanimagedensityfailure
•
Attheoccurrenceofaspottedimage
Adj/set/operatemethod
Enterthesettingvalue,andthenpressOKkey.
Caution
Donotusethiswhenthemachineisoperatingcorrectly.
Display/adj/setrange
-10to10
Unit
50Vpp
Appropriatetargetvalue
-5to5
Defaultvalue
0
Requiredtime
-
Relatedservicemode
COPIER>ADJUST>HV-PRI>OFSTACY2,OFSTACM2,
OFSTACC2
Relatedusermode
-
Supplement/memo
-
8
T-8-29
8
HV-TR
COPIER>ADJUST>HV-TR
1TR-TGY
AdjofprmrytrnsATVCYtargetcurrent
Lv.2
Details
ToadjusttheoffsetofthetargetcurrentforYuponprimary
transferATVCcontrol.
Asthevalueisincrementedby1,theoffsetisincreasedby2uA.
Increasethevalueifspottymarkormottledimageoccurs.
Decreasethevalueifwhitespotsoccur.
Usecase
Whenanimagefailureduetotheprimarytransferoccurs
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
-50to50
Unit
1uA
Appropriatetargetvalue
-10to10
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
1TR-TGM
AdjofprmrytrnsATVCMtargetcurrent
Lv.2
Details
ToadjusttheoffsetofthetargetcurrentforMuponprimary
transferATVCcontrol.
Asthevalueisincrementedby1,theoffsetisincreasedby2uA.
Increasethevalueifspottymarkormottledimageoccurs.
Decreasethevalueifwhitespotsoccur.
Usecase
Whenanimagefailureduetotheprimarytransferoccurs
Adj/set/operatemethod
1)Enterthesettingvalue(switchnegative/positiveby-/+key)
andpressOKkey.
2)TurnOFF/ONthemainpowerswitch.
Caution
-
Display/adj/setrange
-50to50
Unit
1uA
Appropriatetargetvalue
-10to10
Defaultvalue
0
Requiredtime
-
Relatedservicemode
-
Relatedusermode
-
Supplement/memo
-
8-203