12 February 1992
Check the continuity between CN190 and CN460.
Good
Replace the bin side plate H.P. sensor.
Check the bin side plate release sensor. (between CN190-2 and the ground)
Good
≥ 4.0 V
≤ 1.0 V
Check the continuity between CN190 and CN465.
Good
Replace the bin side plate release sensor.
Replace the main control board.
No good
Repair the harness.
No good
< 4.0 V
> 1.0 V
No good
Repair the harness.
61
SERVICE CALL CONDITIONS