PROCESS CONTROL
12 February 1992
Low Temp.
V
Data correction
R
correction
Exposure lamp
Development bias
Grid bias voltage
voltage
voltage
Over 25°C
No correction
No correction
No correction
25°C or lower Lamp voltage + 1V
V
level + 1
V
level + 1
R
R
1.5.2 Low Temp. Correction
When a correction is required under low temperature conditions, the CPU
increases the exposure lamp voltage by 1V.
1.5.3 V
Data Correction
R
When the low temp. correction is applied, V
data correction is applied
R
simultaneously. The V
correction level for both the grid bias voltage and the
R
development bias voltage is stepped up by 1. This means the negative
voltage for the charge grid and the development bias is increased by 40V.