Ricoh FT5233 Service Manual page 693

Table of Contents

Advertisement

12 February 1992
19. Remove the grip cover [A] (2 screws).
20. Adjust the height of the magnet catch on each side. Repeat the
following procedure for each magnet catch:
1) Loosen the screws securing the magnet catch [B] (2 screws).
2) Close the document feeder and tighten the magnet catch screws when
the rubber stopper [C] touches the exposure glass.
21. Reinstall the grip cover.
[A]
[C]
25
INSTALLATION
[B]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ft5433Ft5733

Table of Contents