Ricoh FT5233 Service Manual page 340

Table of Contents

Advertisement

OTHERS
10.1.2 Vacuum Fan Filters
1. Turn off the main switch.
2. Remove the rear cover.
3. Remove the ozone filter [A]
NOTE: The PM interval of this paper ozone filter is 80K copies.
4. Swing out the dc power supply board.
5. Unhook the high voltage cables from the vacuum fan bracket [B] and
disconnect the vacuum fan harness [C] (1 connector).
6. Remove the vacuum fan bracket (2 screws).
7. Remove the vacuum fan [D] (2 screws).
8. Replace the ozone filter [E].
NOTE: The PM interval of this ceramic ozone filter is 400K copies.
9. Reinstall the vacuum fan and install the new ozone filter.
[B]
[E]
[D]
5-110
12 February 1992
[C]
[A]