12 February 1992
4.
CLEANING
4.1
CLEANING UNIT REMOVAL
[A]
[B]
1. Open the front door and lower the transfer & separation corona unit [A] by
pulling down the release lever [B].
2. Place a sheet of paper under the cleaning unit.
3. Turn the cleaning unit release lever [C] counterclockwise.
4. While holding up the cleaning blade release lever [D], pull out the
cleaning unit [E]. Place the unit on a clean sheet of paper.
[C]
5-29
[E]
CLEANING
[D]