REPLACEMENT AND ADJUSTMENT
16.2 GRIP ASSEMBLY REMOVAL AND GRIP SOLENOID
ADJUSTMENT
16.2.1 Grip Assembly Removal
[C]
1. Open the front cover [A].
2. Remove the proof tray [B] (5 screws) and front cover [C] (4 screws).
3. Move the grip assembly [D] between the 1st bin and 7th bin by turning the
knob [E].
4. Remove the stapler [F] by pressing up the stapler release lever [G].
5. Remove the frame connector cover [H] (2 screws).
6. Disconnect the 3 connectors [I] and remove the staple harness [J] (2
screws) from the frame connector cover.
[E]
[D]
[B]
[G]
[A]
34
[H]
[J]
12 February 1992
[F]
[I]