12 February 1992
10.14 INVERTER SOLENOID ADJUSTMENT
[B]
Adjustment Standard:1.5±0.5 mm
1. Remove the feed-out unit. (Refer to Feed-Out Unit Removal.)
2. Hold down the inverter solenoid bar [A] to measure the gap [B].
3. If the gap is not within specifications, take the following steps.
4. Loosen the solenoid bracket screw [B].
5. Adjust the gap by sliding the inverter solenoid assembly
REPLACEMENT AND ADJUSTMENT
[A]
43
[B]