PROCESS CONTROL
12 February 1992
The drop of drum sensitivity due to the drum wear is compensated by V
L
correction. V
correction is performed more often than V
correction,
L
G
therefore, V
correction is not applied to the exposure lamp voltage, only to
G
the grid bias voltage.