COPIER INSTALLATION
[A]
[B]
5. Remove the left scale [A] (2 shoulder screws).
6. Remove the scanner lock pin [B] simply by pulling it up from the front and
the rear side of the left scale bracket.
7. Reinstall the left scale.
8. Remove the left optics cover [C] (1 screw).
9. Remove the scanner lock plate [D] (1 screw) by pulling and lifting it up
and reinstall the left optics cover.
10. Remove the shipping retainer [E] holding the ozone filter. The retainer is
taped on the upper exit cover.
[C]
[E]
3-6
12 February 1992
[D]