Ip Pim Rp-Candidate - D-Link DGS-6600-48T Cli Reference Manual

Modular layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600-48T:
Table of Contents

Advertisement

DGS-6604

ip pim rp-candidate

ip pim rp-candidate INTERFACE-ID [ group-list ACCESS-LIST-NAME ] [interval SECONDS]
[priority PRIORITY]
no ip pim rp-candidate [INTERFACE-ID ]
Syntax Description
INTERFACE-ID
group-list ACCESS-
LIST-NAME
interval SECONDS
priority PRIORITY
Default
Command Mode
Usage Guideline
Example
CLI Reference Guide
Use this command to configure the router as an RP candidate. Use the no form
of this command to remove the router as a candidate RP.
Specifies the interface ID. The IP address associated with this interface is
advertised as a candidate RP address.
(Optional) Specifies the name of the multicast access list that defines the group
prefixes that are advertised in association with the RP address. If no group-list is
specified, the switch is a candidate RP for all groups.
(Optional) Indicates the RP candidate advertisement interval. The range is from
1 to 16383 seconds. The default value is 60 seconds.
(Optional) Indicates the RP priority value. The range is from 0 to 255. The default
value is 192.
The router is not an RP candidate by default.
interval: 60 seconds
priority: 192
Global configuration
This command is valid for SM mode.
Only one group access list can be specified for the command.
The command can be applied multiple times, each for a different interface.
This command causes the router to send a PIM Version 2 message advertising
itself as a candidate RP to the BSR.
Use this command only in backbone routers that have good connectivity to all
parts of the PIM domain. That is, a stub router that relies on an on-demand dialup
link to connect to the rest of the PIM domain is not a good candidate RP.
The following example (on the next page) shows how to configure the router to
advertise itself as a candidate RP to the BSR in its PIM domain. A basic IP
ip pim rp-candidate