Erpi Timer - D-Link DGS-6600-48T Cli Reference Manual

Modular layer 3 chassis ethernet managed switch
Hide thumbs Also See for DGS-6600-48T:
Table of Contents

Advertisement

DGS-6604
m

erpi timer

erpi INSTANCE-ID timer [guard MILLI-SECONDS] [hold-off MILLI-SECONDS] [wtr MINUTES]
no erpi INSTANCE-ID timer [guard] [hold-off] [wtr]
Syntax Description
INSTANCE-ID
guard MILLI-
SECONDS
hold-off MILLI-
SECONDS
wtr MINUTES
Default
Command Mode
Usage Guideline
Example
Switch(config-erps-domain)# erpi 1 timer guard 600
Switch(config-erps-domain)#
Switch(config-erps-domain)# erpi 1 timer guard 700 hold-off 100
Switch(config-erps-domain)#
Switch(config-erps-domain)# erpi 1 timer wtr 1
Switch(config-erps-domain)#
CLI Reference Guide
Use the erpi timer command to configure timers for an ERP instance. Use the no
form of this command to reset timer to default value.
Specifies the identifier of the ERP instance. The valid range is1 to 4095.
Specifies the guard timer in milliseconds. The valid range is 10 to 2000. The
value should be a multiple of 10.
Specifies the hold-off timer in milliseconds. The valid range is 0 to 10000. The
value should be a multiple of 100.
Specifies the WTR timer in minutes. The valid range is 1 to 12.
The default guard timer is 500 milliseconds.
The default hold-off timer is 0.
The default WTR timer is 5 minutes.
ERPS domain configuration mode
Use the command to configure timers for the ERP instance
The following example shows how to configure guard timer to "600 ms" of ERP
instance 1:
The following example shows how to configure guard timer to 700 milliseconds,
hold-off timer to 100 milliseconds of ERP instance 1:
The following example shows how to configure WTR timer to 1 minutes of ERP
instance 1:
erpi timer
193

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dgs-6604Dgs-6600 series

Table of Contents