7.5 Error codes

Common error codes
Error code
4097
4098
4099
4100
4101
4197
4198
4199
4200
4202
4203
4204
4205
4206
4207
4208
Application manual - PickMaster® Twin - PowerPac
3HAC064218-001 Revision: B
Type
Description
Error
Undefined error
Reason: The occurred error has not been given a correct error
ID but the error message should explain the reason.
Status
Information only
Error
Command line options
Reason: PickMaster was given an unknown command line
option, e.g. /p, at startup.
Error
Description: Unexpected error
Reason: An unexpected error occurred in PickMaster. See
the log message for more information.
Error
XML parsing error
Reason: There was a problem reading either a pmline or
pmproj file. See the log message for further information about
where in the file the error occurred.
Error
The project has been upgraded to a later version and the file
is marked as modified. The file needs to be saved to make
changes permanent.
Error
The line has been upgraded to a later version. If the line itself
was opened it is marked as modified and needs to be saved.
If a project was opened, the line should be opened and saved
before continuing.
Error
The project file has an invalid format. It was either created
with a beta version of PickMaster or the file is corrupt.
Error
The PickMaster program failed to access the Windows registry
when writing or reading its configuration
Warning
The project is not designed on the current line. When trying
to open a project, there is already a project open that is built
upon a different line.
Reason: Only one line can be used at the same time.
Solution: Close any open projects and try to open the project
again.
Error
Failed to load the corresponding line when opening a project.
The line file may be corrupt
Error
Failed to load a line. The file may be corrupt.
Error
The imported line may need to be recalibrated
Reason: If the imported line was designed with other cameras
or lenses, the cameras as well as the robot's base frame must
be recalibrated.
Error
The selected RIS plug-in could not be loaded at program
startup. The file may be corrupt.
Error
The selected RIS plug-in could not be found at program
startup.
Error
One of the previously available lines has been overwritten by
another line. The old line will not show up as an available line
and projects designed on that line cannot be used.