ABB PickMaster Twin - PowerPac Applications Manual page 434

Table of Contents

Advertisement

7 Troubleshooting
7.5 Error codes
Continued
Error code
4209
4210
4211
4212
4213
4216
4217
4218
4297
4298
4300
4301
4302
4303
4304
4305
Continues on next page
434
Type
Description
Error
The line file is invalid and cannot be opened.
Error
Failed to load resources for the selected language. The default
language (English) will be used instead
Status
A notification about the total number of picks done by a robot
until the project was stopped.
Error
Failed to remove the line file. The file must be removed
manually.
Warning
Failed to find the html help file for the selected language.
Make sure the "Application manual xxx.chm" file is in the
Documentation folder in the PickMaster folder.
Error
An attempt to open a file not recognized by PickMaster.
Error
No time synchronization service available.
Reason: The PickMaster Time Synchronization Service
might not be properly installed or not started.
Solution: Verify the service is installed and try to restart the
service.
Warning
Two or more network adapters are configured on the same
subnet: x.x.x
Refer to the user guide and review the recommended network
settings.
Status
Attempt to start a project that is already running.
Status
Attempt to stop a project that was not started.
Error
A camera is currently in use by another project.
Reason: When starting a project, one of the position sources
is configured with a camera that is currently in use by another
project.
Solution: A camera can only be used in production in one
project at the same time. Reconfigure one project or run them
one at a time.
Error
Failed to start project execution
Reason: Internal error probably caused by out of memory.
Solution: Try restarting the PickMaster program.
Error
When starting a project, a vision defined position source has
no camera defined.
Solution: Either remove the position source or configure it
with the camera to use.
Error
When starting a project, a position source has no work area
defined
Solution: Either remove the position source or configure it
with the work area to use
Warning
When starting a project, a vision defined position source has
no configured vision models.
Solution: Either remove the position source or define which
vision models to use.
Error
When starting a project, a predefined position source has no
object defined.
Solution: Edit the position source and define the predefined
object to use.
Application manual - PickMaster® Twin - PowerPac
© Copyright 2021 ABB. All rights reserved.
3HAC064218-001 Revision: B