Application manual - PickMaster® Twin - PowerPac
3HAC064218-001 Revision: B
Type
Description
Error
Failed to set the IO signal ppaExe.
Solution: Ensure that the signal ppaExe exists and is set-up
correctly.
Error
Failed to set the RAPID variable "RoutineName" to "NewS-
ource".
Reason: The variable "RoutineName" is probably missing or
is of the wrong type (should be a string type).
Solution: Ensure that the variable exists and is of the string
type.
Error
The system failed to apply the new robot speed.
Error
Failed to set the IO signal doTune.
Solution: Ensure that the signal doTune exists and is set-up
correctly.
Error
The system failed to apply a new work area tune.
Solution: Verify that the following RAPID variables exist.
Num SourceIndex
Num TunePosX
Num TunePosY
Num TunePosZ
Error
Failed to load the RAPID program.
Solution: Verify that there are no errors in the RAPID program
(otherwise it will fail to load).
Error
Failed to download the RAPID program to the controller.
Error
Failed to stop execution of the RAPID program.
Error
Failed to delete the RAPID program.
Error
Failed to reset emergency stop.
Error
Failed to restart the RAPID program.
Solution: Stop the project and restart it.
Error
Failed to get local IP address.
Reason: The network set-up is not correct (e.g. wrong IP
settings, faulty network adapter configuration, etc.).
Solution: Solve the local network problem on the computer.