ABB PickMaster Twin - PowerPac Applications Manual page 443

Table of Contents

Advertisement

Error code
12319
12321
12322
12323
12324
12325
12326
12329
12330
12331
12332
12333
12334
12337
12341
12342
Application manual - PickMaster® Twin - PowerPac
3HAC064218-001 Revision: B
Type
Description
Error
External model failed to inspect image.
Reason: See log message for more information
Error
When the line was opened, more than one camera was
defined to use the same port on the same frame grabber.
Only one camera can be configured to use a single camera
port and hence the other cameras were reset and must be
configured again.
Error
When the line was opened, a camera was defined on a frame
grabber that was not available. The camera was reset and
must be configured again.
Error
Could not initiate the camera. More information is provided
in the log message.
Error
Failed to save camera configuration. More information is
provided in the log message
Error
Failed to load camera configuration. More information is
provided in the log message.
Error
Failed to load vision model configuration. More information
is provided in the log message
Warning
Failed to communicate with Gigabit Ethernet camera.
Reason: Bad Ethernet connection or excessive Ethernet
communication.
Warning
Images are triggered too frequently.
Solution: Adjust vision models to be less time consuming, or
decrease trigger frequency.
Warning
Connection to camera is lost, attempting to reconnect.
Reason: Ethernet cable or power cable has been disconnec-
ted.
Warning
Image Buffer Full. More information is provided in the log
message.
Warning
A Gigabit Ethernet camera was found, but no such license
was detected.
Reason: No USB stick with vision license is inserted in the
PC.
Warning
A license for Gigabit Ethernet vision was detected, but no
such camera was found.
Reason: Camera is not connected, not turned on, or has an
invalid IP-address.
Warning
Failed to read parameter from camera.
Reason: Check if the appropriate Cognex Drivers are installed.
If the problem persits, check network connections.
Status
Cognex USB License dongle is attached.
Warning
Cognex USB License dongle is removed.
© Copyright 2021 ABB. All rights reserved.
7 Troubleshooting
7.5 Error codes
Continued
443

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pickmaster twin

Table of Contents