Restartingthedevice; Restorethefactorydefaultsettings; Video Port Settings; Querythestatusofsourceports - Lightware HDMI-TPS-RX110AY Series User Manual

Hdbaset multimedia extender
Table of Contents

Advertisement

 
7.LW3Programmers'Reference
7.4.7. Restarting the Device
Thereceivercanberestarted–thecurrentconnections(LAN,RS-232,USB)willbeterminated.
Command and Response
#restart #reboot
Î CALL·/SYS:reset()
Í mO·/SYS:reset=
Example
Î CALL/SYS:reset()
Í mO/SYS:reset=
7.4.8. Restore the Factory Default Settings
Command and Response
#factory
Î CALL·/SYS:factoryDefaults()
Í mO·/SYS:factoryDefaults=
Example
Î CALL/SYS:factoryDefaults()
Í mO/SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the default settings are restored. See the
complete list in the
Factory Default Settings
section.
Appliedfirmwarepackage:v1.4.0 | LDCsoftware:v2.4.0b3
HDMI-TPS-RX110AY series – User's Manual
7.5. Video Port Settings
INFO:

VideoportnumberingcanbefoundintheInput/OutputPortNumbering
7.5.1. Query the Status of Source Ports
Command and Response
#portstatus
Î GET·/MEDIA/VIDEO/XP.SourcePortStatus
pr·/MEDIA/VIDEO/XP.SourcePortStatus=<in_state>
Í
Theresponsecontains5ASCIIcharactersforeachport.Thefirstcharacterindicatesthemute/lockstate,
the next four characters represent a 2-byte HEX code showing the current state of the input ports.
Example
Î GET/MEDIA/VIDEO/XP.SourcePortStatus
Í pr/MEDIA/VIDEO/XP.SourcePortStatus=M00AA
Parameters
Letter(Character1)
Mute state
Lockstate
T
Unmuted
L
Unmuted
M
Muted
U
Muted
Character 2
BIT 7-6
Reserved
0 0
0 1
1 0
Reserved
1 1
Letter
Mute / Lock status
Unlocked
Reserved character, always 0.
Byte 1
Locked
Reserved character, always 0.
Unlocked
Embedded audio / HDCP status
Byte 2
Signal present / Connection status
Locked
Byte 1
Character 3
Character4
BIT5-4
BIT 3-2
BIT 1-0
BIT 7-6
Embedded
Reserved
Reserved
Reserved
HDCP status
audio status
No
embedded
Reserved
Reserved
Reserved
encrypted
audio
Embedded
audio
Encrypted
presents
70
section.
M
0 0 A A
Byte 2
Character 5
BIT5-4
BIT 3-2
BIT 1-0
Signal
Connection
present
status
status
Unknown
Reserved
Not
Not
No signal
connected
Signal
Connected
presents