7.LW3Programmer'sReference
7.8.6. RS-232 Operation Mode
ATTENTION!
TheRS-232Operation modeismirroredontheLocalandLinkserialport.
Command and Response
#commandinjection
SET·/MEDIA/UART/<port>.Rs232Mode=<mode>
pw·/MEDIA/UART/<port>.Rs232Mode=<mode>
Parameters
Identifier
Parameterdescription
<mode>
The current operation mode
oftheRS-232ports.
ATTENTION!
Forback-compatibilityreasonsanotherpropertyhastobesetincaseofCommandinjection
mode.Seethefollowingsection.
Example
SET/MEDIA/UART/P1.Rs232Mode=1
pw/MEDIA/UART/P1.Rs232Mode=1
INFO:
SeemoreinformationaboutRS-232modesintheSerialInterface
7.8.7. Command Injection Mode
WhentheportistobeoperatedinCommandinjectionmodethefollowingcommandmustbealsoset.
Command and Response
#commandinjection
SET·/MEDIA/UART/<port>.CommandInjectionEnable=<CI_set>
pw·/MEDIA/UART/<port>.CommandInjectionEnable=<CI_set>
Parameters
Setthe<CI_set>
parameter to 1 or true toenabletheCommandInjectionmode.
Example
SET/MEDIA/UART/P1.CommandInjectionEnable=1
pw/MEDIA/UART/P1.CommandInjectionEnable=1
Parametervalues
0:Pass-through, 1:Control,
2:Commandinjection
section.
Appliedfirmwarepackage:v1.2.0 | LDCsoftware:v2.2.0
HDMI-TPS-TX200series–User'sManual
7.9. Infrared Port
INFO:
Infraredinputandoutputportnumberingcanbefoundinthe
7.9.1. Enable Command Injection Mode
Command and Response
SET·/MEDIA/IR/<port>.CommandInjectionEnable=<CI_set>
pw·/MEDIA/IR/<port>.CommandInjectionEnable=<CI_set>
Parameters
Setthe<CI_set>
parameter to 1 or true toenabletheCommandInjectionmode.
Example
SET/MEDIA/IR/S1.CommandInjectionEnable=1
pw/MEDIA/IR/S1.CommandInjectionEnable=true
7.9.2. Enable/Disable Output Signal Modulation
Command and Response
SET·/MEDIA/IR/<out>.EnableModulation=<mod_set>
pw·/MEDIA/IR/<out>.EnableModulation=<mod_set>
Parameters
Setthe<mod_set>
parameter to 1 or true toenablethemodulationonthedestinationIRport.
Example
SET/MEDIA/IR/D1.EnableModulation=0
pw/MEDIA/IR/D1.EnableModulation=false
Explanation
SignalmodulationisturnedoffonIRoutput(D1).
PortNumbering
#infra
#infrared
84
section.