KEB COMBIVERT F5 Original Manual
KEB COMBIVERT F5 Original Manual

KEB COMBIVERT F5 Original Manual

Brake transistor monitor
Hide thumbs Also See for COMBIVERT F5:

Advertisement

Quick Links

COMBIVERT F5
INSTRUCTION MANUAL | BRAKE TRANSISTOR MONITOR
Original manual
Brake Transistor Monitor
Document 20231183 USA 00
Material No. 00F5LUZ-K004

Advertisement

Table of Contents
loading

Summary of Contents for KEB COMBIVERT F5

  • Page 1 COMBIVERT F5 INSTRUCTION MANUAL | BRAKE TRANSISTOR MONITOR Original manual Brake Transistor Monitor Document 20231183 USA 00 Material No. 00F5LUZ-K004...
  • Page 2 2020 KEB America, Inc. ©...
  • Page 3: Preface

    Preface 1 Preface The hardware described in this document is a product of KEB America, Inc. The information contained in this document is valid at the time of publishing. KEB reserves the right to update this document in response to misprints, mistakes or technical changes.
  • Page 4: Laws And Requirements

    1.4 Warranty KEB America Inc. provides a limited warranty on all products. This warranty can be found in the terms and conditions at our website. KEB America, Inc. Terms and Conditions Terms and Conditions Further agreements or specifications require written confirmation from KEB America, Inc.
  • Page 5: Table Of Contents

    Climatic Environment Conditions ..................14 4.1.2 Mechanical Ambient Conditions ..................14 4.1.3 Electrical Operating Conditions ..................15 4.1.3.1 Device Classification ....................... 15 4.1.3.2 Electromagnetic Compatibility ..................15 Rated Values ....................16 5 Installation ................... 17 2020 KEB America, Inc. ©...
  • Page 6 DC Brake Resistor Contactor ..................20 5.2.2.2 AC Line Contactor ......................21 6 Appendix ....................22 Appendix 1: Recommended Distribution Block TB ........22 Appendix 2: Recommended DC Contactor ..........22 7 Revision History .................. 22 2020 KEB America, Inc. ©...
  • Page 7: List Of Figures

    List of Figures Figure 1: Dimensions ..........................17 Figure 2: Mounting Dimensions ........................18 Figure 3: Terminals ............................. 19 Figure 4: Wiring Diagram: DC Contactor ....................20 Figure 5: Wiring Diagram: AC Contactor ....................21 2020 KEB America, Inc. ©...
  • Page 8: List Of Tables

    Table 1: Climatic environment conditions ....................14 Table 2: Mechanical ambient conditions ..................... 14 Table 3: Device classification ........................15 Table 4: Electromagnetic compatibility ....................... 15 Table 5: Rated values ..........................16 Table 6: Terminal Connections ........................19 2020 KEB America, Inc. ©...
  • Page 9: Glossary

    Glossary Glossary Application The machine or device Device, the See KEB Product in which the KEB product is being installed. Brake Resistor Resistor used to absorb KEB Product The KEB device excess energy resulting described in this from the moving...
  • Page 10: Standards For Brake Transistor Monitor

    Personal safety code detailing appropriate personal protective equipment for working on electrical installations. OSHA 1910.269 • Region: US Occupational safety code detailing safety standards for electrical power generation, transmission, and distribution. B44.1-19/ASME A17.5-2019 • Region: US and Canada Elevator and Escalator Electrical Equipment 2020 KEB America, Inc. ©...
  • Page 11: Safety Instructions

    The following safety instructions have been created by KEB America, Inc. for the Brake Transistor Monitor. These instructions can be supplemented by local, country- or application-specific safety instructions where relevant.
  • Page 12: Electrical Safety Guidelines

    When using components without isolated inputs/outputs, equipotential bonding • must be used between the connected components. Failure to provide adequate equipotential bonding may result in the destruction of the components by equalizing currents. 2020 KEB America, Inc. ©...
  • Page 13: Product Description

    Model Number : 00F5090-BTW9 • 3.2 Overview The KEB Brake Transistor Monitor is designed to monitor the status and health of the Brake transistor of the connected AC drive. Brake transistors are generally robust and appropriately sized for loads in excess of continuous duty.
  • Page 14: Technical Data

    Acceleration amplitude 10 m/s2 (9 to 200 Hz) EN 61800-5-1 Vibration amplitude 0.075 mm (10 to 57 Hz) Acceleration amplitude 10 m/s2 (57 to 150 Hz) Shock limit values EN 60721-3-3 100 m/s2 Table 2: Mechanical ambient conditions 2020 KEB America, Inc. ©...
  • Page 15: Electrical Operating Conditions

    EN 6100-4-6 0.15 to 80 MHz disturbances induced by radio-frequency fields Electromagnetic fields EN 61000-4-3 10V/m 80 MHz to 1 GHz 3V/m 1.2 to 2 GHz 1V/m 2 to 2.7 GHz Table 4: Electromagnetic compatibility 2020 KEB America, Inc. ©...
  • Page 16: Rated Values

     If the control voltage applied to contacts K1 and K2 is 120VAC, the safe insulation between the 24VDC supply and the contacts K1/K2 is reduced to basic insulation. As a result the entire 24V control circuit of the drive is reduced to basic insulation according to UL61800-5-1. 2020 KEB America, Inc. ©...
  • Page 17: Installation

    Installation 5 Installation 5.1 Mounting 5.1.1 Dimensions Figure 1: Dimensions 2020 KEB America, Inc. ©...
  • Page 18: Mounting

    Mounting Distance Dimension Distance (mm) Distance (inch) * Distance to preceeding elements in the control cabinet door Figure 2: Mounting Dimensions 2020 KEB America, Inc. ©...
  • Page 19: Electrical Installation

    Tightening Torque DC Power Stranded conductor with wire-end ferrule. 0.8 Nm Supply 0.13 to 4 mm 7.0 in lbs UL stranded conductor. 26 to 10 AWG Normally-Closed Contact Pilot Duty Rated Table 6: Terminal Connections 2020 KEB America, Inc. ©...
  • Page 20: Wiring Diagrams

    Two conductors shall not be joined to one terminal.  To connect the Brake Transistor Monitor, an external distribution or connection block (TB) must be used to connect the Brake resistor and the Brake Transistor Monitor in parallel. 2020 KEB America, Inc. ©...
  • Page 21: Ac Line Contactor

    Two conductors shall not be joined to one terminal.  To connect the Brake Transistor Monitor, an external distribution or connection block (TB) must be used to connect the Brake resistor and the Brake Transistor Monitor in parallel. 2020 KEB America, Inc. ©...
  • Page 22: Appendix

    Used for the parallel connection of the brake resistor and the Brake Transistor Monitor. • Two single-phase distribution blocks are required. nVent ERIFLEX UD-80A 569010 https://www.erico.com/part.asp?part=UD-80A KEB Material Number 0090503-5001 6.2 Appendix 2: Recommended DC Contactor • Used to disconnect the BR- connection to the brake resistor. GIGAVAC® GV250 Series Contactor https://www.gigavac.com/sites/default/files/catalog/spec_sheet/gv250.pdf KEB Material Number 0090215-2601 6.3 Revision History...
  • Page 24 Belgium | KEB America, Inc. Herenveld 2 9500 Geraardsbergen Belgium P.R. China | KEB Power Transmission Technology (Shanghai) Co. Ltd. No. 435 QianPu Road Chedun Town Songjiang District Tel: +32 544 37860 Fax: +32 544 37898 201611 Shanghai P.R. China E-Mail: vb.belgien@keb.de...
  • Page 25 Automation with Drive www.kebamerica.com KEB America, Inc. 5100 Valley Industrial Blvd S Shakopee, MN 55379 Tel. +1 952-224-1400 E-Mail: info@kebamerica.com...

Table of Contents