Goodrive3000 series medium voltage inverters
Function
Name
code
P01.00
Reserved
Main contactor
switching-on
P01.01
feedback
detection
Undervoltage
P01.02
setting value of
input voltage
Overvoltage
P01.03
setting value of
input voltage
P01.04
Reserved
P01.05
Reserved
Waiting time of
P01.06
automatic
operation
Delay time of
P01.07
automatic fault
reset
P01.08
Fault reset times
P03 Group Control parameters
P03.00
Reserved
P03.01
Reserved
P03.02
Reserved
P03.03
Reserved
P03.04
Reserved
P03.05
Reserved
Positive limit
amplitude of active
P03.06
current
(rectification)
Negative limit
P03.07
amplitude of active
current (feedback)
Positive limit
amplitude of
P03.08
reactive current
(rectification)
Negative limit
amplitude of
P03.09
reactive current
(feedback)
P03.10
Maximum current 0~250.0% (rated current of
Detailed parameter
description
0: No detection
1: Detection
75.0~95.0%
105.0~125.0%
0~3600.0s
0.0~3600.0s
0~10
0.0~200.0% (rated current of
the rectifier)
0.0~200.0% (rated current of
the rectifier)
0.0~200.0% (rated current of
the rectifier)
0.0~200.0% (rated current of
the rectifier)
-49-
Goodrive3000 series PWM rectifier
Setting
Default Modify No.
range
0~1
1
75.0~95.0%
85.0%
105.0~125.0%
115.0%
0~3600.0
0.0s
0.0~3600.0
1.0s
0~10
0
0.0~200.0%
150.0%
0.0~200.0%
150.0%
0.0~200.0%
150.0%
0.0~200.0%
150.0%
0~250.0%
200.0%
●
17.
◎
18.
●
19.
●
20.
●
21.
●
22.
○
23.
○
24.
○
25.
●
26.
●
27.
●
28.
●
29.
●
30.
●
31.
○
32.
○
33.
○
34.
○
35.
○
36.
Need help?
Do you have a question about the Goodrive3000 GD3000-01-055G-12 and is the answer not in the manual?