Goodrive3000 series medium voltage inverters
P08 Group Enhanced functions
Function
Name
code
P08.00
ACC time 2
P08.01
DEC time 2
P08.02
ACC time 3
P08.03
DEC time 3
P08.04
ACC time 4
P08.05
DEC time 4
Refer to P00.11 and P00.12 for detailed definitions.
Goodrive3000 series define four groups of ACC/DEC time which can be selected by the multi-function
digital input terminals (P05). The first group of ACC/DEC time is the factory default one.
Function
Name
code
P08.06
Jogging frequency
The parameter is used to define the frequency reference during jogging.
Function
Name
code
P08.07
Jogging ACC time
P08.08
Jogging DEC time
Jogging ACC time is the time required by the inverter which accelerates from 0Hz to the maximum
frequency (P00.03).
Jogging DEC time is the time required by the inverter which decelerates from the maximum frequency
(P00.03) to 0Hz.
Function
Name
code
Jumping frequency
P08.09
1
Jumping frequency
P08.10
range 1
Jumping frequency
P08.11
2
Jumping frequency
P08.12
range 2
Jumping frequency
P08.13
3
Detailed parameter description
0.0~3600.0s
0.0~3600.0s
0.0~3600.0s
0.0~3600.0s
0.0~3600.0s
0.0~3600.0s
Detailed instruction of parameters
0.00~P00.03 (Max. frequency)
Detailed instruction of parameters
0.0~3600.0s
0.0~3600.0s
Detailed instruction of parameters
0.00~P00.03 (Max. frequency)
0.00~P00.03 (Max. frequency)
0.00~P00.03 (Max. frequency)
0.00~P00.03 (Max. frequency)
0.00~P00.03 (Max. frequency)
-110-
Goodrive3000 series converter
Setting range
Default
Depend
0.0~3600.0
on model
Depend
0.0~3600.0
on model
Depend
0.0~3600.0
on model
Depend
0.0~3600.0
on model
Depend
0.0~3600.0
on model
Depend
0.0~3600.0
on model
Default
Setting range
value
0.00~P00.03
5.00Hz
Default
Setting range
value
Depend
0.0~3600.0
on model
Depend
0.0~3600.0
on model
Default
Setting range
value
0.00~P00.03
0.00Hz
0.00~P00.03
0.00Hz
0.00~P00.03
0.00Hz
0.00~P00.03
0.00Hz
0.00~P00.03
0.00Hz