Function
Name
code
Integral ratio of
P08.43
the keypad
potentiometer
UP/DOWN
P08.44
terminal control
UP terminal
frequency
P08.45
changing ratio
DOWN terminal
frequency
P08.46
changing ratio
Action when the
frequency
P08.47
setting is at
power off
Detailed instruction of parameters
0: Effective setting
1: Effective during running, cleared
after stopping
2: Effective during running, cleared
after receiving the stop command
LED thousands: ∧/∨ and digital
potentiometer integral function
0: Effective integral function
1: Ineffective integral function
0.01~10.00s
0x000~0x221
LED ones: Frequency control
selection
0: UP/DOWN terminal setting
effective
1: UP/DOWN terminal setting
ineffective
LED tens: Frequency control selection
0: Only effective when P00.06=0 or
P00.07=0
1: Effective for all frequency setting
manners
2: Ineffective for multi-step speed
when multi-step speed has the priority
LED hundreds: Action selection
during stopping
0: Effective setting
1: Effective during running, cleared
after stopping
2: Effective during running, cleared
after receiving the stop command
0.01~50.00s
0.01~50.00s
0x000~0x111
LED ones: Action selection when the
digital adjusting frequency is at power
off
0: Save when the power is off
1: Clear when the power is off
LED tens: Action selection when
MODBUS setting frequency is at
power off
0: Save when the power is off
-181-
Goodrive3000 series converter
Default
Setting range
value
0.01~10.00
0.10s
000~221
0x000
0.01~50.00
0.50s
0.01~50.00
0.50s
0x000~0x111
0x000
Modify No.
○
337.
○
338.
○
339.
○
340.
○
341.