ABB IRB 6620LX Product Manual page 270

Hide thumbs Also See for IRB 6620LX:
Table of Contents

Advertisement

4 Repair
4.6.6 Replacement of motor, axis 6
Continued
11
Replacement of the motor axis 6 (Foundry Plus)
Robots with protection type Foundry Plus require special repair routines to maintain
the tightness level.
The repair must be done according to the previous repair procedure with the
following additions.
1
2
3
Continues on next page
270
Action
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in the section
First test run may cause
injury or damage on page
Action
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
Remove the rear motor cover by unscrewing
the five attachment screws.
Continue to remove the motor unit, according
to step 6 and forwards in
page
267.
© Copyright 2009-2018 ABB. All rights reserved.
Note
26.
Note
xx1500002524
Removal, motor on
A: Motor unit
B: Connection box
C: Attachment screw (5 pcs)
D: Rear motor cover
E: Gasket
Product manual - IRB 6620LX