Removal
The procedure below details how to remove the cable harness.
1
2
3
4
5
Product manual - IRB 6620LX
3HAC035737-001 Revision: P
Action
Decide which calibration routine to use, and
take actions accordingly prior to beginning
the repair procedure.
In order to facilitate refitting of the cable
harness, run the robot to the specified pos-
itions:
Axis 1: no significance
Axis 2: 0°
Axis 3: 0°
Axis 4: 0°
Axis 5: +90°
Axis 6: no significance
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the ro-
bot
air pressure supply to the robot
Before entering the robot working area.
Before starting the removal of cable harness
axes 3-6, first remove cable harness axes
1-2.
Remove the cover, wrist unit in order to
reach the cable harness at axes 5 and 6.
Note
Foundry Plus
Make sure not to lose the washers placed
in the holes of the foundry gasket.
xx1400002580
© Copyright 2009-2018 ABB. All rights reserved.
4.3.3 Replacement of cable harness, upper end
Note
Detailed in the section
cable harness, lower end (axes 1-2) on
page
189.
xx0600003024
A : Cover, wrist unit
4 Repair
Continued
Replacement of
Continues on next page
197