E
F
G
H
Required equipment
Equipment, etc.
Battery pack
Standard toolkit
Circuit diagram
Removing, battery
Use this procedure to remove the SMB battery.
1
2
3
Product manual - IRB 6620LX
3HAC035737-001 Revision: P
SMB/BU box
Connection point, battery cable
SMB (Serial measurement board)
BU unit (Brake release unit)
Note
There are two variants of SMB units and batteries. One with 2-pole battery contact
and one with 3-pole battery contact. The variant with the 3-pole battery contact
has longer lifetime for the battery.
It is important that the SMB unit uses the correct battery. Make sure to order the
correct spare parts. Do not replace the battery contact!
Spare part no.
For spare part no.
see:
-
-
Action
Move the robot to its calibration position.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working area.
xx0200000023
WARNING
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the sec-
tion
The unit is sensitive to ESD on page 31
© Copyright 2009-2018 ABB. All rights reserved.
Note
Battery includes protection circuits. Only re-
place with a specified spare part or an ABB-
Spare part
approved equivalent.
lists on
page 351
Content is defined in section
on page
See chapter
3 Maintenance
3.4.9 Replacing the SMB battery
Continued
Standard tools
348.
Circuit diagram on page
Note
This is done in order to facilitate