5
Programming Command Reference
MS External Control Signal
CONFigure:MSEXt H/L|L/H|H/H|L/L
CONFigure:MSEXt?
This command sets the signal level of the MS External Control
Signal. The parameter is H/L, L/H, H/H, or L/L. At preset, this is
set to H/L.
This query command returns the signal level setting of the MS
External Control Signal.
Panel Key Control
CONFigure:PKEY UNLOCK|LOCK
CONFigure:PKEY?
This command sets the panel key control to UNLOCK or LOCK. At
preset, this is set to UNLOCK. If this is set to LOCK, only
Automatic Test and Configuration are available. In Automatic
Test, Radio System, BCCH and TCH (Talk) are locked and
cannot be changed.
This command is not identical to Lock System Panel of the System
commands. See
Lock System
Panel.
This query command returns the panel key control setting by
string of UNLOCK or LOCK.
Printer Control
CONFigure:PRINter PMG800|USBMemory
CONFigure:PRINter?
This command sets the output direction of the Print Screen. The
parameter is PMG800 or USBMemory. At preset, this is set to
USBMemory. Preset (*RST) is invalid.
This query command returns a type of printer or destination
with strings.