N9360A Multi UE Tester CDMA2000 Programming Manual
bit 8 (256) :Band Change
Each bit is set to 0 if the test is pass, or each bit is set to 1 if the
test is fail. If there are no test results, all bits are set to 1 and the
value 511 is returned.
The value in the parentheses is decimal value for each bit. Refer
to
Setting and Querying the
TESTs:MANual:RESults:SIGNaling:EXPand?
The return value of this query command differs depending on
the CDMA mode (MC1X or EVDO).
When CDMA mode is MC1X:
This query command returns summary of the test results with
integer value of <int 1> and <int 2>.
<int 1> contains Signaling Result of Manual test by sum of the
value of 10 bits as follows:
bit 0 (1) :Location Update
bit 1 (2) :MS Call
bit 2 (4) :MS Release
bit 3 (8) :BS Call
bit 4 (16) :BS Release
bit 5 (32) :Connection
bit 6 (64) :Softer Handoff
bit 7 (128) :Hard Handoff
bit 8 (256) :Band Handoff
bit 9 (512) :System Handoff
Each bit is set to 0 if the test is pass, or each bit is set to 1 if the
test is fail. If there are no test results, all bits are set to 1 and the
value 1023 is returned.
The value in the parentheses is decimal value for each bit. Refer
to
Setting and Querying the
<int 2> contains the system type currently being executed.
The return value is 2 (cdma2000), 1 (W-CDMA), or 0 (GSM).