Agilent Technologies N9360A Programming Manual page 170

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

5
Programming Command Reference
5-120
When CDMA mode is EVDO:
This query command returns the test step currently executed in
a test cycle. The return value contains the currently executed
status of 11 bits as follows:
bit 0 (1) :BS Call
bit 1 (2) :RF Test
bit 2 (4) :Connection Close
bit 3 (8) :Time out error (Currently unused)
bit 4 (16) :End (Stand-by status)
bit 5 (32) :UATI Assignment
bit 6 (64) :Session Opened
bit 7 (128) :Session Close
bit 8 (256) :Busy
bit 9(512):Softer Handoff
bit 10(1024):Channel Change/Band Change
The executed step is set to 1, and the others are set to 0. The
value in the parentheses is decimal value for each bit. Refer to
Setting and Querying the
TESTs:MANual:SIGNaling:STATe:EXPand?
The return value of this query command differs depending on
the CDMA mode (MC1X or EVDO).
This query command returns the test contents currently being
executed and system type with integer value of <int 1> and
<int 2>.
When CDMA mode is MC1X:
<int 1> contains test contents currently being executed by
sum of the value of 10 bits as follows:
bit 0 (1) :MS Call/ BS Call
bit 1 (2) :Talk, RF Test
bit 2 (4) :MS Release/BS Release
bit 3 (8) :Time out error (Currently unused)
bit 4 (16) :End (Stand-by status)
bit 5 (32) :Location Update
bit 6 (64) :Busy
bit 7 (128) :Softer Handoff
N9360A Multi UE Tester CDMA2000 Programming Manual
Registers.

Advertisement

Table of Contents
loading

Table of Contents