Programming Command Reference
5-128
Multi-code Rho Measurement
TESTs:MANual:RESults:MRHO?
This query command is valid in the following case:
When CDMA mode is set to EDVO, or When CDMA mode is set to
MC1X and F3R3, F4R3, or F5R4 is set by the Radio Configuration"
command.
This query command returns the Multi-code Rho Measurement
result values, <int 1>, <int 2>, and <real 3>.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or Multi-code Rho is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
• <real 3> (up to 5 letters) is the measured data ranging
from 0.800 to 1.000. If measurement result is out of range
or Multi-code Rho is not measured, the value 9.999 is
returned.
Origin Offset Measurement
TESTs:MANual:RESults:OriginOFFset?
This query command returns the Origin Offset Measurement result
values, <int 1>, <int 2>, and <real 3>. Each value is
separated by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or Origin Offset is not measured.
• <int 2> (1 digit) is the test result for the 0 (pass) or 1 (fail).
• <real 3> (up to 5 letters) is the measured data ranging
from -99.9 to 0.0 in dBc. If measurement result is out of
range or Origin Offset is not measured, the value 99.9 is
returned.
Sensitivity/FER Measurement
TESTs:MANual:RESults:FER?
This query command is valid when CDMA mode is set to MC1X.
This returns the Sensitivity/FER Measurement result values,
<int 1>, <int 2>, <int 3>, <int 4>, and <real 5>.