Agilent Technologies N9360A Programming Manual page 164

Multi ue tester
Hide thumbs Also See for N9360A:
Table of Contents

Advertisement

5
Programming Command Reference
5-114
Rho/Origin Offset
TESTs:MANual:RHO:STATe ON|OFF|1|0
TESTs:MANual:RHO:STATe?
This command is valid when CDMA mode is set to MC1X. This
sets whether to execute the Rho/Origin Offset test when F1R1 or
F2R2 is set by the Radio Configuration command. The parameter
is ON (1) or OFF (0). At preset, this is set to 1.
This query command returns the setting of the Rho/Origin Offset
test with integer value of 1 or 0. The meaning of the return
value is same as that of the command parameter.
Multi-code Rho/Origin Offset
TESTs:MANual:MRHO:STATe ON|OFF|1|0
TESTs:MANual:MRHO:STATe?
This command is valid in the following case:
When CDMA mode is set to EDVO, or When CDMA mode is set to
MC1X and F3R3, F4R3, or F5R4 is set by the Radio Configuration
command.
This sets whether to execute the Multi-code Rho/Origin Offset test.
The parameter is ON (1) or OFF (0). At preset, this is set to 1.
This query command returns the setting of the Multi-code
Rho/Origin Offset test with integer value of 1 or 0. The meaning
of the return value is same as that of the command parameter.
Sensitivity/FER
TESTs:MANual:FER:STATe ON|OFF|1|0
TESTs:MANual:FER:STATe?
This command is valid when CDMA mode is set to MC1X. This
sets whethert to execute the FER test. The parameter is ON (1)
or OFF (0). At preset, this is set to 1.
This query command returns the setting of the FER test with
integer value of 1 or 0. The meaning of the return value is same
as that of the command parameter.
N9360A Multi UE Tester CDMA2000 Programming Manual

Advertisement

Table of Contents
loading