N9360A Multi UE Tester CDMA2000 Programming Manual
Code Domain Power DRC Measurement
TXANalyzer:RESults:CDPWr:DRC?
This query command returns the DRC CH measurement result
values, <int 1>, <int 2>, and <real 3> on the [Code
Domain Power] measurement screen. Each value is separated
by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or Code Domain Power is not measured.
• <int 2> (1 digit) is the test result for the pass (0) or fail (1).
(Judgment of limit value is not executed.)
• <real 3> (up to 5 letters) is the measured data ranging
from -40.0 to 0.0 in dB. If measurement result is out of
range or Code Domain Power is not measured, the value
99.9 is returned.
Code Domain Power DRC (EXPand) Measurement
TXANalyzer:RESults:CDPWr:DRC?
This query command returns the DRC CH measurement result
values, <int 1>, <int 2>, <real 3> and <real 4> on the [Code
Domain Power] measurement screen.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or Code Domain Power is not measured.
• <int 2> (1 digit) is the test result for the pass (0) or fail (1).
(Judgment of limit value is not executed.)
• <real 3> (up to 5 letters) is the measured data ranging
from -40.0 to 0.0 in dB. If measurement result is out of
range or Code Domain Power is not measured, the value
99.9 is returned.
<real 4> (up to 5 letters) is the measured data (relative to Pilot
CH) ranging from -40.0 to 0.0 in dB. If measurement result is
out of range or Code Domain Power is not measured, the value
99.9 is returned.
Code Domain Power ACK Measurement
TXANalyzer:RESults:CDPWr:ACK?