Code Domain Power RRI (EXPand) Measurement
TESTs:MANual:RESults:CDPWr:RRI:EXPand?
This query command is valid when CDMA mode is set to EVDO.
This returns the RRI CH measurement result values, <int 1>,
<int 2>, <real 3> and <real 4> on the [Code Domain Power]
measurement screen.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or Code Domain Power is not measured.
• <int 2> (1 digit) is the test result for the pass (0) or fail (1).
(Judgment of limit value is not executed.)
• <real 3> (up to 5 letters) is the measured data ranging from
-40.0 to 0.0 in dB. If measurement result is out of range or
Code Domain Power is not measured, the value 99.9 is
returned
• <real 4> (up to 5 letters) is the measured data (relative level
to Pilot CH) ranging from -40.0 to 0.0 in dB. If
measurement result is out of range or Code Domain Power is
not measured, the value 99.9 is returned.
Code Domain Power DRC Measurement
TESTs:MANual:RESults:CDPWr:DRC?
This query command is valid when CDMA mode is set to EVDO.
This returns the DRC CH measurement result values, <int 1>,
<int 2>, and <real 3> on the [Code Domain Power]
measurement screen. Each value is separated by a comma.
• <int 1> (1 digit) is 0 if measurement result is within the
measurement range, or 1 if measurement result is out of
range or Code DomainPower is not measured.
• <int 2> (1 digit) is the test result for the pass (0) or fail (1).
(Judgment of limit value is not executed.)
• <real 3> (up to 5 letters) is the measured data ranging
from -40.0 to 0.0 in dB. If measurement result is out of
range or Code DomainPower is not measured, the value 99.9
is returned.